Gas Bottle-Cylinder Testing Facts

Learn everything about LPG from Australia’s largest LPG provider. Explore our attractive home value plans and sign up for ELGAS LPG today.

New to ELGAS? Explore great deals here

NEW TO
ELGAS?

Save this Winter! Check out our Home LPG plans HERE

Home 9 SWAP’n’GO® Blogs 9 Gas Bottle-Cylinder Testing Facts

22 Aug, 2024 | SWAP’n’GO® Blogs

In this article:

Get the facts on gas bottle-cylinder testing. The testing procedures, ten-year expiry, internal & external physical inspection and more...

Gas Cylinder Testing Facts – Gas Bottle Expiry: LPG Expiry Date

Gas Cylinder Testing - LPG Expiry Date

Gas cylinder testing must be done every ten years because of the LPG expiry date.

It is illegal to fill a gas bottle that is past its gas bottle expiry but you are allowed to use it, past the LPG expiry date, if it still contains gas.

What is Gas Cylinder Testing & Expiry (Gas Bottle Testing & Expiry)

In summary:

• Gas bottles, cylinders and larger tanks must be inspected periodically for safety and re-certification.

• Gas bottle expiry periods vary, with 10 years being the most common.

• Gas cylinder test date is permanently marked or stamped on the bottle.

• The gas bottles are subject to internal and external inspection for rust and any other damage.

• Physical testing, including pressure tests, may be required depending on the type and size of vessel and the country where tested.

• The main valve is typically replaced when a gas bottle is inspected for re-certification.

• A new gas cylinder test date, of equivalent duration, is stamped into the neck ring after re-inspection.

• Only approved gas cylinder testing facilities are authorised to test and re-certify gas bottles, cylinders and tanks.

Gas Cylinder Testing Procedures & Inspection: Step-by-Step Summary

The following is a step-by-step summary of gas cylinder testing and inspection:

  1. Determination that the cylinder inspection date has reached its expiry.
  2. External inspection of cylinder is performed.
  3. Cylinder is degassed to allow for internal inspection.
  4. Old valve is removed and an internal inspection is done.
  5. The cylinder neck and valve threads are inspected for any damage.
  6. A new test date is stamped into the cylinder neck ring.
  7. A new valve is installed.
  8. Any required refurbishment, including painting, is performed.
  9. The cylinder is ready for refilling and return to use.
  10. Any cylinders that failed the test, at any point, are condemned and recycled.

Please note that if at any time a cylinder fails part of the test, they condemn the cylinder without bothering to do any further gas cylinder testing.

Continue reading to learn the details involved in each step…

Gas Bottle Expiry – LPG Expiry Date – How to Find the Date Stamp

Gas Bottle Expiry - LPG Expiry Date

Gas bottle expiry is the LPG expiry date for LPG bottles or cylinders.

Gas bottle expiry periods vary – with 10 to 15 years being typical.

Expired gas bottles can be used but cannot be refilled.

To determine the gas bottle expiry, you need to inspect the gas bottle’s neck ring.

The cylinder manufacturer places the original inspection stamp on the neck ring at the time of manufacture.

For BBQ sized cylinders, the inspection and the stamp are valid for ten years prior to expiry.

After ten years, and any subsequent ten year periods, the cylinder must be reinspected.

The cylinder ‘test station’ will stamp a new inspection date into the neck ring, assuming that the cylinder passes inspection.

So, it is always important to examine the entire neck ring to find all of the dates that may be present, as it is impossible to remove the old stamps.

 

External Inspection

LPG gas bottle condemned because of fire damage

The external surface of the gas bottle is inspected for defects, as defined by the applicable Standard, AS 2337.1-2004.

 
The kind of things they look for are swelling of the cylinder walls, the depth and diameter of any dents, the length and depth of any gouges, the depth and intensity of any corrosion, the presence of any cracks, or any damage from fire or heat.
 
Failure in any one category is cause for condemning the gas bottle.
 
The gas bottle in the picture was condemned for fire damage.
 

Preparation – De-gassing

At the start of the process the gas bottle is totally emptied of any remnant gas.

A degassing station is shown in the picture to the right.
 
The old gas valve is then removed to facilitate the internal inspection.
 

Internal Inspection

LPG gas bottle with corroded cylinder neck area

A flexible scope, with illumination, is used to inspect the inside of the gas bottle.

 
The interior is inspected for rust, scale, corrosion or any contamination.
 
Normally, if the bottle has been kept either full of LPG or empty with the valve closed, internal rust and corrosion are not a problem.
 
Any gas bottle that fails to meet the Standard is condemned.
 

Cylinder Neck

The neck of the gas bottle is a critical area, as it is the point of attachment for the valve.
 
The valve threads are inspected to see if they are clean and intact, damage free, free of burrs and cracks or any other imperfections that could affect the integrity of the connection.
 
Once again, failure in any area is cause for condemnation.
 

New Date Stamping

Test station stamping tool

Gas bottles that pass all of the tests are stamped with a new inspection date, showing the month and last two digits of the year.
 
In addition the test station stamps its own unique test station mark onto the gas bottle.
 
Both stamps are typically applied in previously unmarked areas of the neck ring, as shown to the right.
 

Valve Installation

LPG gas bottle valve removal and insertion tool

The next step is the installation of a new valve, as shown in the picture.

 
The old valves are discarded and recycled.
 

Refilling

While not part of the formal inspection process, the new valve installation should always be leak tested when refilled.

In fact, this is the standard procedure for all subsequent refilling, as well.

__________________________________________

Additional Swap Scheme Procedures

Swap programs, such as SWAP’n’GO®, also refurbish the gas bottles before they are refilled.

 

Refurbishment

LPG gas bottles on an automated paint line

In addition to the normal test procedures, over half of the bottles tested by SWAP’n’GO would also be repainted.

Many would also be shot blasted prior to painting.

The end result is a refurbished gas bottle in near new condition, with a new test date stamp that is valid for ten more years.

The picture shows gas bottles being repainted on an automated coating line.

 

Recycling

Condemned gas bottles with large punctures for safe decommissioning

SWAP’n’GO bottles that are condemned are safely retired by punching a large hole in the side, so the metal recycling workers know that they have been safely decommissioned.
 
 
 
 
In addition to recycling the steel from the gas bottles, the brass from the valves is also recycled.